Piercing

Piercing Needle Gauges and Receiving Tubes: Size Chart

Updated
Reading
6 min
Sources
6 cited
Written by
Medical Plus Team
Needle pusher, receiving tubes and piercing tools from Medical Plus

In the US, body jewelry and piercing needles are usually sized in gauge, and most American piercers use the Brown and Sharpe / American Wire Gauge (AWG) system[2]. The higher the gauge number, the thinner the wire[1]. This guide gives a gauge-to-millimeter chart and explains how to match needles to receiving tubes, needle pushers and tapers.

Quick answer 18g is about 1.0 mm, 16g about 1.3 mm, 14g about 1.6 mm, 12g about 2.1 mm and 10g about 2.6 mm. For a receiving tube, the needle has to pass through the tube's inner diameter (ID), so check the ID or the "accepts needles up to" size on the listing, not just the gauge stamped on the tube.

How does gauge sizing work for piercing needles and jewelry?

Gauge numbers come from wire drawing. In the American Wire Gauge, the numbers run backwards: a larger number denotes a smaller wire[1]. The scale is fixed at two ends, with No. 0000 defined as 0.4600 inch and No. 36 as 0.0050 inch, and the sizes in between follow a constant ratio[1].

Gauge is the US convention. The APP notes that most other countries measure jewelry thickness in millimeters, and above 00 gauge US sizes switch to fractions of an inch[2][3]. The steps between gauges are not even: going from 14g to 12g adds about 0.43 mm, while 4g to 2g adds about 1.36 mm[3].

What is each piercing gauge in millimeters?

Quick answer Use the chart below. Figures are the AWG diameters from the US National Bureau of Standards wire table[1], converted at exactly 25.4 mm per inch[6] and rounded to two decimals.

American Wire Gauge (AWG) to inches and millimeters
Gauge Inches Millimeters
22g 0.0253 0.64
20g 0.0320 0.81
18g 0.0403 1.02
16g 0.0508 1.29
14g 0.0641 1.63
12g 0.0808 2.05
10g 0.1019 2.59
8g 0.1285 3.26
6g 0.1620 4.11
4g 0.2043 5.19
2g 0.2576 6.54
0g 0.3249 8.25
00g 0.3648 9.27

Suppliers sometimes list a rounded metric figure next to a gauge. Our own slant-cut receiving tubes, for example, list the 0G tube as 8 mm outside diameter, against 8.25 mm in the AWG table.

Is a piercing needle gauge the same as a medical needle gauge?

Quick answer Not necessarily. Medical needle tubing has its own sizing standard, and the same gauge number can mean a different diameter. Always compare millimeters.

Medical needle tubing is covered by ISO 9626, which specifies tubing of designated metric sizes from 3.4 mm (10 gauge) down to 0.18 mm (34 gauge)[5]. In the AWG table, 10 gauge is 2.59 mm[1]. So the gauge number alone doesn't tell you two products will fit together. If a needle, tube or piece of jewelry lists a diameter in mm, use that.

How do you match a receiving tube to your needle?

Quick answer The needle must pass through the tube's inner diameter. On our double-sided tubes the listing states the largest needle each tube accepts; on our slant-cut tubes it gives the outside and inside diameter.

Needle receiving tubes (NRTs) are used to support and protect the tissue during piercing, and they are usually hollow stainless steel tubes with smooth openings, sometimes flared or angled[2]. The gauge stamped on a tube describes the tube, not the needle it takes. That is why a "4G" tube is used with a smaller needle.

Double-sided piercing receiving tube with 45 and 30 degree angled ends, Medical Plus
Double-Sided Piercing Receiving Tube: a 45° end and a 30° end on one tube. Each size lists the largest needle it accepts.
Our receiving tubes and the needles they take
Tube size Double-sided 45°/30°: accepts needles up to Slant-cut 45°: OD / ID
10G 16G (MP-6172) Not offered
8G 14G (MP-6171) 3 mm / 2 mm (MP-6173)
6G 10G (MP-6170) 4 mm / 2.7 mm (MP-6174)
4G 8G (MP-6169) 5 mm / 3.5 mm (MP-6175)
2G 6G (MP-6168) 6 mm / 4.7 mm (MP-6176)
0G 4G (MP-6167) 8 mm / 5.8 mm (MP-6177)
00G Not offered 10 mm / 8 mm (MP-6178)

To use the slant-cut column, compare the ID with the chart above. A 4G slant-cut tube has a 3.5 mm ID, and an 8g wire size is 3.26 mm, so an 8g needle of nominal size passes through.

Which needle pusher and taper sizes do you need?

Quick answer Pick a needle pusher whose gauge range covers the needles you use, and choose tapers by millimeter size to match the jewelry.

Stainless steel needle pusher with T-bar handle for 20G to 8G piercing needles, Medical Plus MP-6185
Needle Pusher (MP-6185): a T-bar handle that presses on the needle hub, for 20G to 8G needles.

What should a studio check before ordering?

  1. Gauge range. List the needle gauges you actually pierce with, then pick tubes, pushers and tapers that cover them.
  2. Millimeters. Where a listing gives OD and ID, compare those with the chart rather than relying on the gauge label.
  3. Labeling. The APP manual says sterilized needles should be individually packaged and labeled with gauge and date of sterilization[2].
  4. Sterility. The APP states that all tools, needles and jewelry must be sterile, and all needles must be single-use[4].
  5. Tube material. The APP manual notes that glass and plastic tubes can become compromised and should be treated as single-use[2]. Our tubes are stainless steel and reusable when cleaned and sterilized according to your protocol.

Featured in this guide

See the full ranges in Piercing Receiving Tubes, Piercing Tapers and the wider Piercing collection.

FAQ

Does a lower gauge number mean a thicker needle?

Yes. In the American Wire Gauge a larger number denotes a smaller wire[1], so 12g is thicker than 14g.

Is 0g the same as 8 mm?

Close, but not exact. In the AWG table 0 gauge is 8.25 mm[1]. Some listings round to 8 mm, so check the millimeter figure when fit matters.

Why does a "4G" receiving tube take an 8G needle?

The gauge names the tube, and the needle has to fit inside it. Our listings give either the largest needle each tube accepts or the tube's inner diameter.

Can I reuse receiving tubes?

Our stainless steel tubes are reusable when cleaned and sterilized according to your protocol. Needles are single-use[4], and the APP manual suggests treating glass and plastic tubes as single-use[2].

Sources

  1. National Bureau of Standards (now NIST) – Handbook 100: Copper Wire Tables (1966). NBS Handbook 100 (PDF)
  2. Association of Professional Piercers – Procedure Manual, 2013 Edition (2013). APP Procedure Manual (PDF)
  3. Association of Professional Piercers – Stretching (undated web page). safepiercing.org
  4. Association of Professional Piercers – Piercing FAQ (undated web page). safepiercing.org
  5. International Organization for Standardization – ISO 9626:2016, Stainless steel needle tubing for the manufacture of medical devices — Requirements and test methods (2016). iso.org
  6. National Institute of Standards and Technology – SI Units: Length (undated web page). nist.gov

General questions about ordering

Can Medical Plus instruments be autoclaved and reused?

Our stainless-steel surgical, electrosurgical and piercing instruments are made for repeated use and are compatible with standard steam sterilization (autoclaving) when they are cleaned and maintained properly. Follow the instructions supplied with the instrument and your facility's or studio's protocol, and check the Key Specs on the product page. If you are unsure about a coated instrument, contact us before autoclaving it.

What are the instruments made of?

Stainless steel, as listed in the Key Specs on each product page. Some piercing forceps and clamps have a dip-molded jaw coating in nylon or DEHP-free plastisol, and selected forceps come in gold, black or rainbow plasma finishes.

How quickly do orders ship?

Catalog orders are processed within 1–3 business days after payment confirmation. Delivery then takes 3–7 business days in the U.S. and 7–21 business days internationally. Details are in our Shipping Policy.

Do you offer bulk or volume pricing?

Yes. We quote volume pricing for hospitals, surgical centers, distributors, piercing studios and OEM partners. Email info@medicalplusinc.com or call 516-450-0879 with the catalog numbers (MP-…) and quantities you need.

Can you make a custom size, coating or private-label instrument?

Yes, subject to manufacturing feasibility and minimum order quantities. Custom OEM, private-label and large bulk orders typically take 4–10 weeks depending on complexity, materials and volume. See Custom & OEM manufacturing.

Can I get a sample before placing a larger order?

Samples are available for qualified medical facilities, distributors and OEM partners. Email info@medicalplusinc.com to request one.

What is your return policy?

Defective or damaged items reported within 7 business days of receipt can be returned if they are unused, in the original packaging and with proof of purchase. Single-use and sterilized instruments cannot be returned. Full details are in our Refund Policy.

How do I check that an instrument matches the one I already use?

Compare the pattern name, overall length and tip or jaw size on the product page with your current instrument. If you are still unsure, send us the catalog number (MP-…) and we will confirm the fit.